REACON
| Availability: | |
|---|---|
| Quantity: | |
The REACON GWR-12/36 Outdoor AC High Voltage Disconnect Switch is designed for electrical isolation in medium-voltage power distribution networks and outdoor substations. With a rated current of 630A and a product configuration specified for 24kV applications, this isolating switch provides a visible disconnection point for electrical equipment during maintenance, inspection and system servicing.
The outdoor disconnect switch is designed with an insulated support structure, conductive contact components and a mechanical operating arrangement. Its construction helps maintain electrical insulation and mechanical stability under different outdoor environmental conditions.
The main conductive components provide a reliable current path when the switch is in the closed position. When operated, the moving contact separates from the fixed contact to create an isolation gap, allowing maintenance personnel to identify the disconnected circuit section.
The GWR-12/36 series is suitable for overhead power distribution lines, outdoor substations, utility electrical installations and industrial medium-voltage networks. Its galvanized metal components provide additional corrosion protection, while the outdoor insulation structure is designed to withstand environmental exposure.
REACON provides high-voltage disconnect switch solutions for different distribution network configurations, with product selection based on rated voltage, current, installation arrangement and project requirements.
The outdoor AC disconnect switch consists of several functional components that work together to provide electrical isolation.
Insulating Support
The insulating components support the conductive parts and maintain the required electrical clearance between energized components and the mounting structure.
Fixed and Moving Contacts
The contact assembly establishes the electrical connection when the switch is closed. During opening operation, the moving contact separates from the fixed contact to form a visible isolation gap.
Conductive Components
The conductive contact parts are designed to provide an electrical current path with controlled contact pressure and suitable electrical conductivity.
Mechanical Operating Mechanism
The operating mechanism transfers manual operating force to the moving contact assembly, allowing the switch to be opened or closed according to the prescribed operating procedure.
Galvanized Metal Frame
The metal support and mounting components provide mechanical support. Hot-dip galvanized hardware helps protect exposed metal surfaces against corrosion in outdoor installations.
Reliable Electrical Isolation
The switch provides a visible physical separation point when opened, helping maintenance personnel identify isolated electrical sections.
Outdoor Insulation Performance
The insulating support structure is designed for outdoor medium-voltage applications and helps maintain electrical insulation under specified environmental conditions.
Corrosion-Resistant Hardware
Hot-dip galvanized metal components offer protection against corrosion and environmental exposure, supporting long-term outdoor installation.
Stable Mechanical Operation
The operating arrangement is designed to provide controlled opening and closing movements with consistent mechanical performance.
630A Current Rating
The 630A rated-current configuration is suitable for compatible medium-voltage power distribution applications.
Flexible Installation Arrangement
The switch can be selected for suitable outdoor mounting structures according to project drawings, electrical clearances and installation requirements.
The disconnect switch is designed for outdoor installation under the following specified service conditions:
• Maximum installation altitude: 2,000m.
• Ambient temperature: -40°C to +40°C.
• Maximum wind speed: 32m/s.
• Earthquake intensity: Not exceeding 8 degrees.
• Installation environment: Without frequent severe mechanical vibration.
• Ordinary type: Installation locations should avoid excessive chemical deposits, corrosive gases, salt spray and conductive contamination.
• Pollution-resistant type: Available for suitable contaminated environments, subject to product configuration.
The actual service conditions should be reviewed during product selection to ensure compatibility with the installation environment.

The REACON GWR-12/36 outdoor disconnect switch is suitable for various medium-voltage electrical installations.
Outdoor Substations
Used to provide visible electrical isolation for selected equipment sections, including compatible transformer and circuit breaker connections.
Overhead Distribution Networks
Installed at designated points in overhead distribution systems to separate electrical sections during maintenance and system inspection.
Utility Power Infrastructure
Suitable for electrical isolation arrangements in utility distribution networks and outdoor switching installations.
Industrial Power Distribution
Used in industrial substations and medium-voltage distribution facilities where equipment isolation is required.
Electrical Equipment Maintenance
Provides a visible isolation point after the associated circuit has been safely de-energized, helping establish appropriate maintenance conditions.
| No. | Item | Unit | Data | ||
| 1 | Rated voltage | kV | 12,36 | ||
| 2 | Rated current | A | 630 | ||
| 3 | Rated power frequency | Hz | 50/60 | ||
| 4 | Rated peak withstand current | kA | 60,63 | ||
| 5 | Rated short-time withstand current | kA | 20,25 | ||
| 6 | Rated short-time withstand current duration | S | 4 | ||
| 7 | Main loop resistance | μ Ω | 12kV≤90 | 36kV≤100 | |
| 8 | 1min.PF withstand voltage(dry) | Phase to phase/ earth across open contacts | kV | 42/48 30 75/85 | 95/115 85 185/215 |
| 9 | 1min.PF withstand voltage(wet) | ||||
| 10 | Lightning impulse withstand voltage | ||||
| 11 | Mechanical life | Times | 200 | ||
Proper installation and operation are essential for the safe performance of a high-voltage disconnect switch.
Step 1: Installation Preparation
Check the installation drawings, mounting dimensions, electrical clearances and foundation or support structure before installation.
Step 2: Mechanical Mounting
Secure the switch assembly to the designated outdoor mounting structure using the specified fixing hardware. Verify the alignment of the insulating supports and operating mechanism.
Step 3: Electrical Connection
Connect the incoming and outgoing conductors to the designated terminals using compatible electrical connectors. Confirm conductor compatibility and terminal fastening requirements.
Step 4: Mechanical Inspection
Check the contact alignment, operating linkage, fastening components and opening/closing movement according to the manufacturer’s installation instructions.
Step 5: Electrical Commissioning
Perform the required insulation resistance, contact resistance and mechanical operation inspections before energizing the equipment.
Step 6: Safe Isolation During Maintenance
Before operating the disconnect switch, ensure the associated circuit breaker or load switching device has interrupted the load current. Follow the approved switching procedure, verify the absence of voltage and apply grounding measures as required.
Important: A standard disconnect switch is not intended to interrupt normal load current or fault current. It must not be used as a substitute for a load break switch or circuit breaker.
REACON focuses on material control, dimensional accuracy and mechanical performance during the production of outdoor high-voltage disconnect switches.
Product inspection can cover the following items:
• Visual inspection of insulating and conductive components.
• Dimensional verification of mounting and contact assemblies.
• Inspection of mechanical operating components.
• Contact resistance measurement.
• Insulation performance testing.
• Mechanical operation and endurance inspection.
• Verification of galvanized metal components.
Applicable inspection and testing requirements can be agreed upon according to the project specification and relevant standards.
REACON also supports customized configurations according to customer drawings, rated electrical parameters and installation requirements.
Q1: What is the rated current of the GWR-12/36 disconnect switch?
A1: The product is listed with a rated current of 630A. The actual application should be checked against the approved technical specification.
Q2: What is the main function of an outdoor high-voltage disconnect switch?
A2: Its main function is to provide electrical isolation by creating a visible physical separation between electrical circuit sections. It is commonly used during equipment maintenance and inspection.
Q3: Can this disconnect switch interrupt load current?
A3: A standard disconnect switch is designed for no-load isolation rather than normal load-current interruption. The associated circuit breaker or suitable load switching device must interrupt the current before the isolator is operated.
Q4: Is the GWR-12/36 suitable for outdoor installation?
A4: Yes. It is designed for outdoor electrical installations, including distribution networks and substations. The appropriate insulation and pollution-resistance configuration should be selected according to site conditions.
Q5: What is the difference between a disconnect switch and a load break switch?
A5: A disconnect switch provides electrical isolation and a visible open gap, while a load break switch is designed to make and interrupt specified load currents within its rated operating conditions.
Q6: Can REACON customize the disconnect switch?
A6: REACON can discuss customized product requirements according to rated voltage, rated current, installation dimensions, mounting arrangements and customer drawings.
Q7: What information is required for a product quotation?
A7: Customers are advised to provide the required voltage rating, rated current, installation environment, operating mechanism, quantity and technical drawings when available.
REACON supplies electrical equipment and components for power transmission and distribution systems, including outdoor disconnect switches, circuit breakers, fuse cutouts, insulators, surge arresters and pole line hardware.
For the GWR-12/36 outdoor disconnect switch, customers can contact REACON with project specifications and technical requirements to confirm the suitable configuration.
Technical drawings, product specifications and customized solutions can be discussed according to individual project needs.