The REACON Oil Immersed BTA/HTA Transformer is designed for electrical distribution systems that require dependable voltage transformation and continuous power supply. It transfers electrical energy between medium or high voltage networks and low-voltage distribution circuits, making it suitable for utility infrastructure, industrial facilities, and commercial power systems.
The transformer uses insulating oil as both an electrical insulation medium and a cooling medium. Heat generated by the core and windings is transferred through the oil to the tank and cooling surfaces, helping maintain stable operating temperatures under normal load conditions.
Its internal structure consists of a magnetic core, high-voltage and low-voltage windings, an insulating system, and an oil-filled tank. Depending on the installation requirements, the transformer can be supplied with different tank structures, terminal arrangements, protection components, and cooling configurations.
REACON provides oil-immersed transformer solutions for distribution projects with different voltage levels, capacity requirements, and installation environments.
Insulating oil surrounds the active components, providing electrical insulation while carrying heat away from the core and windings. This combined function supports thermal management and stable transformer operation.
The magnetic core and winding arrangement are designed to support efficient energy transfer. Electrical characteristics can be configured according to the required rated capacity, voltage ratio, and operating conditions.
The transformer tank provides mechanical protection for the internal components and contains the insulating oil. Different tank structures can be selected according to installation conditions and maintenance requirements.
The transformer can be designed for different primary and secondary voltage combinations. Rated capacity, winding materials, tap-changing arrangements, and connection configurations can be selected according to project requirements.
The oil cooling system and enclosed construction support stable operation in utility and industrial distribution networks where reliable electricity supply is essential.
Item | Description |
Product Type | Oil Immersed Distribution Transformer |
Product Series | BTA / HTA |
Transformer Phase | Single Phase / Three Phase |
Rated Capacity | Available in different kVA ratings |
Primary Voltage | Configurable according to project requirements |
Secondary Voltage | Configurable according to distribution standards |
Rated Frequency | 50Hz / 60Hz |
Cooling Method | ONAN or other suitable cooling arrangements |
Winding Material | Copper / Aluminum |
Core Material | Electrical Silicon Steel |
Insulating Medium | Transformer Insulating Oil |
Winding Configuration | Two-Winding Design |
Tap Changing | Off-Circuit Tap Changer or other specified arrangement |
Installation | Indoor / Outdoor, according to design |
Applicable Standard | IEC 60076 series or project-specific standards |
A properly designed magnetic core and winding structure help reduce no-load and load losses. This contributes to efficient energy transfer throughout the distribution process.
Transformer oil circulates naturally or through a specified cooling arrangement, transferring heat from the active components to the external cooling surfaces. This helps control temperature rise during operation.
The insulating oil and internal insulation materials work together to maintain the required dielectric strength between windings and between energized components and the grounded tank.
Different tank configurations, bushings, cable connection arrangements, and protection accessories can be selected to suit substations, industrial power rooms, and outdoor distribution installations.
Depending on the selected design, inspection points and accessories can be arranged to facilitate oil condition checks, temperature monitoring, and routine maintenance.
An oil-immersed BTA/HTA transformer generally consists of the following components:
Component | Function |
Magnetic Core | Provides the magnetic path for energy transfer between windings. |
High-Voltage Winding | Receives electrical energy from the primary power supply. |
Low-Voltage Winding | Delivers transformed voltage to the distribution circuit. |
Transformer Tank | Houses the core, windings, and insulating oil. |
Cooling Radiators | Increase the heat dissipation surface area. |
HV and LV Bushings | Provide insulated electrical connection points. |
Tap Changer | Adjusts the winding ratio to accommodate voltage variations, depending on the selected design. |
Oil Level Indicator | Allows operators to check the insulating oil level. |
Temperature Indicator | Monitors transformer oil or winding temperature, depending on the arrangement. |
Pressure Relief Device | Releases excessive internal pressure when the specified operating threshold is reached. |
The REACON BTA/HTA oil-filled transformer is suitable for different power distribution environments.
Used in distribution substations to transform incoming medium-voltage electricity into a voltage level suitable for local distribution feeders and end users.
Applied in factories, processing plants, and production facilities where electrical equipment requires a stable power supply. It can serve as part of the plant’s main or secondary distribution system.
Suitable for shopping centers, office complexes, public facilities, and other infrastructure projects that require dedicated distribution transformer equipment.
Can be integrated into solar and wind power systems as part of the electrical connection between generation equipment and the distribution network, subject to the project’s voltage and grid requirements.
Used in electricity distribution infrastructure to supply residential areas, agricultural facilities, and remote communities.
Suitable for distribution network expansion, replacement of aging transformer units, and capacity improvement projects.
The oil-immersed transformer is selected and installed according to the electrical design of the distribution system.
First, determine the required rated capacity, primary voltage, secondary voltage, frequency, and connection configuration based on the load characteristics and grid conditions.
Next, select an appropriate installation structure, such as a substation-mounted arrangement or an outdoor installation, and prepare the foundation, electrical connections, and grounding system.
The high-voltage and low-voltage terminals are connected to their corresponding circuits through suitable cables, busbars, or insulated connectors. Required protection equipment and monitoring accessories are arranged according to the electrical system design.
Before energization, the transformer should undergo the specified installation inspections and electrical tests. These include checking terminal connections, grounding, insulation condition, oil level, and protection arrangements.
During operation, regular inspection of oil condition, temperature, leakage, and electrical connections helps maintain safe and consistent performance.
REACON focuses on the manufacturing quality and electrical performance of oil-immersed distribution transformers.
The production process involves core assembly, winding manufacturing, insulation treatment, active-part assembly, tank installation, oil filling, and final inspection.
Quality control may cover the following items according to the applicable product standard and project specification:
• Winding resistance measurement
• Voltage ratio and vector group verification
• No-load loss and no-load current measurement
• Load loss and impedance voltage measurement
• Applied voltage withstand test
• Induced voltage withstand test
• Insulating oil quality inspection
• Tank sealing and leakage inspection
Each transformer is subject to the applicable factory routine tests before delivery. Additional type tests or special tests can be arranged according to the project requirements.
Q1: What is an oil-immersed BTA/HTA transformer used for?
An oil-immersed BTA/HTA transformer is used in electrical distribution networks to transfer power between different voltage levels. Typical applications include utility substations, industrial facilities, commercial infrastructure, and renewable energy installations.
Q2: What is the difference between an oil-immersed transformer and a dry-type transformer?
An oil-immersed transformer uses insulating liquid for both electrical insulation and heat transfer. A dry-type transformer relies on solid insulation and air or other specified cooling arrangements. Oil-filled designs are commonly selected for outdoor distribution and substation applications, while dry-type units are frequently used in buildings and installations with specific fire-safety or environmental requirements.
Q3: Can the transformer be manufactured with copper or aluminum windings?
Yes. Copper and aluminum winding options are available depending on the required electrical performance, design conditions, and project budget.
Q4: Can the primary and secondary voltages be customized?
Yes. The primary and secondary voltage ratings can be configured according to the local distribution network and project specifications.
Q5: What cooling method is used in an oil-immersed distribution transformer?
ONAN (Oil Natural Air Natural) is a commonly used cooling method. Transformer oil circulates naturally inside the tank, while heat is transferred to the surrounding air through the tank walls and cooling radiators.
Other cooling arrangements can be considered for specific transformer designs.
Q6: What maintenance does an oil-immersed transformer require?
Routine maintenance generally includes checking the oil level, inspecting for oil leakage, monitoring operating temperature, examining electrical connections, and testing insulating oil when required. The maintenance interval depends on the operating environment and applicable maintenance standards.
Q7: Does REACON provide transformers for different distribution projects?
Yes. REACON can provide oil-immersed transformer configurations for utility, industrial, commercial, and infrastructure projects. Design options can be selected according to the required voltage, capacity, installation conditions, and technical specifications.
Q8: Can the transformer be supplied with different protection accessories?
Yes. Depending on the transformer design, accessories such as pressure relief devices, oil level indicators, temperature indicators, conservators, and protective relays can be selected to meet the installation and operational requirements.
REACON provides electrical equipment for power transmission and distribution systems, including transformers, insulators, surge arresters, fuse cutouts, disconnect switches, and power line fittings.
For an oil-immersed BTA/HTA transformer quotation, please share your required capacity, voltage ratio, frequency, winding material, and installation conditions. Our team can assist with product selection and technical configuration according to your project requirements.