REACON composite line post insulators are developed for overhead power networks and outdoor electrical installations where dependable insulation and mechanical conductor support are required.
Unlike suspension insulators that primarily carry tensile loads, a line post insulator provides rigid support for conductors and helps maintain the required electrical clearance between energized components and grounded structures.
The product combines a fiberglass reinforced polymer core with an external silicone rubber housing and metal mounting fittings. This construction offers a balance of mechanical rigidity, electrical insulation, and resistance to outdoor environmental exposure.
Different configurations are available for medium and high voltage applications, including 24kV distribution networks and 69kV or 72kV transmission systems. The overall length, shed arrangement, creepage distance, mechanical loading capacity, and connection fittings can be selected according to the electrical and structural requirements of each project.
REACON supplies composite line post insulators for utility networks, outdoor substations, overhead conductor support assemblies, and power infrastructure projects.
The REACON composite line post insulator range covers several voltage classes to accommodate different network designs.
Although these products share a similar composite material structure, their electrical dimensions and mechanical configurations are not necessarily interchangeable.
The 24kV configuration is intended for medium voltage distribution applications.
Its compact supporting structure makes it suitable for overhead distribution networks, pole-mounted installations, and outdoor electrical equipment.
Typical installation locations include distribution poles, crossarms, and supporting structures where conductors must be securely positioned while maintaining electrical separation from grounded components.
The 69kV version is designed for higher electrical stress and the mechanical requirements associated with high voltage overhead networks.
It can be applied to conductor support positions on transmission structures and selected outdoor substation installations.
Compared with medium voltage configurations, higher voltage designs generally require greater insulation dimensions, appropriate creepage distance, and electrical clearances determined by the system insulation coordination.
The 72kV configuration serves high voltage installations requiring rigid conductor support and reliable outdoor insulation.
It is suitable for transmission infrastructure and electrical installations operating at the corresponding voltage class.
The insulator design can be configured with suitable shed profiles, core dimensions, mounting arrangements, and electrical insulation characteristics to meet the requirements of the installation.
In systems using a 72.5kV highest voltage for equipment, the final product configuration should follow the project’s specified insulation level.
The following table summarizes the main differences between the available configurations.
Item | 24kV Type | 69kV Type | 72kV Type |
Voltage Class | Medium Voltage | High Voltage | High Voltage |
Main Application | Distribution Networks | Transmission Networks | High Voltage Transmission |
Installation Position | Distribution Poles and Crossarms | Transmission Structures and Substations | Transmission Structures and Outdoor Equipment |
Insulation Design | Medium Voltage Insulation | Higher Voltage Insulation | Higher Voltage Insulation |
Mechanical Function | Rigid Conductor Support | Rigid Conductor Support | Rigid Conductor Support |
Main Selection Factors | Electrical Clearance and Mechanical Load | Creepage Distance and Cantilever Load | Insulation Level and Structural Requirements |
The three configurations are intended for different electrical applications. Selection should be based on system voltage, maximum equipment voltage, lightning impulse withstand level, pollution conditions, and specified mechanical loading.
The composite construction combines several materials, each serving a different function within the complete insulator assembly.
The internal core is manufactured from fiber-reinforced polymer material, providing the structural rigidity required to support conductors under cantilever and other specified mechanical loads.
Its mechanical characteristics are important for maintaining the position of overhead conductors under operating conditions, including wind and conductor loading.
The external housing consists of silicone rubber sheds arranged along the core.
The shed profile increases the external creepage path and helps control surface insulation performance under wet and contaminated conditions.
Silicone rubber also possesses hydrophobic properties, which help limit the formation of continuous water films on the insulator surface.
Metal fittings connect the insulator to the supporting structure and provide the mounting interface for conductor hardware.
Depending on the design, the assembly can incorporate different top and bottom connection arrangements.
Common configurations include threaded studs, base plates, flanges, and conductor-side fittings.
Metal fittings can be manufactured with protective surface treatments suitable for outdoor electrical installations.
A composite line post insulator must meet both electrical insulation requirements and mechanical support requirements.
The following characteristics are particularly important when selecting a suitable design.
Electrical Insulation Performance
The external insulating surface and shed arrangement are designed to provide the required insulation distance between energized conductors and grounded structures.
The electrical design is determined by the rated system voltage, highest voltage for equipment, power-frequency withstand voltage, and lightning impulse withstand voltage.
Pollution and Wet-Weather Performance
The silicone rubber surface helps maintain hydrophobicity under changing environmental conditions.
This property is particularly useful in coastal areas, industrial regions, and locations exposed to dust or airborne contaminants.
Cantilever Mechanical Strength
As a rigid support insulator, the line post configuration must withstand the specified transverse mechanical loading.
The specified cantilever load is an important selection parameter, particularly where conductor weight, wind pressure, and line arrangement create mechanical stress.
Tracking and Erosion Resistance
The silicone rubber housing is designed to withstand electrical and environmental stresses associated with outdoor service.
Material formulation and shed geometry contribute to resistance against surface tracking and erosion.
Outdoor Environmental Adaptability
The composite structure is suitable for outdoor applications involving sunlight, rain, humidity, temperature variation, and atmospheric contamination.
REACON composite line post insulators can be incorporated into several types of electrical installations.
The 24kV configuration can be used on distribution poles and crossarms to support overhead conductors.
Its rigid structure helps maintain conductor positioning and the required phase-to-ground insulation distance.
The 69kV and 72kV configurations are intended for high voltage installations where mechanical conductor support and electrical insulation must be considered together.
They can be incorporated into suitable transmission structures according to the engineering design.
Line post insulators can support busbars and selected electrical connections in outdoor substations.
The mounting arrangement and mechanical rating must correspond to the equipment layout and applied loads.
In locations exposed to industrial pollution, airborne particles, or salt-containing moisture, silicone rubber composite insulation provides useful hydrophobic surface characteristics.
The final insulation design should take the site’s pollution severity and required creepage distance into account.
Composite line post insulators can also be considered for upgrading existing installations where replacement of conventional insulating components is required.
The mounting dimensions, electrical clearances, and mechanical interface should be checked before installation.
The electrical and mechanical characteristics of a composite line post insulator depend on its voltage class and structural configuration.
REACON can provide different design arrangements according to project specifications.
Important technical parameters include:
Parameter | Description |
Product Type | Composite Line Post Insulator |
Rated Voltage | 24kV / 69kV / 72kV configurations |
Insulating Material | Silicone Rubber |
Core Material | Fiberglass Reinforced Polymer |
Metal Fittings | Galvanized Metal Fittings |
Mechanical Rating | Specified Cantilever Load |
Creepage Distance | Designed according to insulation requirements |
Insulation Level | Power-Frequency and Lightning Impulse Withstand |
Installation | Poles, Crossarms and Substation Structures |
Application | Outdoor Power Transmission and Distribution |
Customized designs can include:
• Different insulator lengths and overall dimensions
• Alternative shed diameters and spacing
• Various creepage distance requirements
• Different specified cantilever loads
• Customized top and bottom fittings
• Project-specific mounting dimensions
• Electrical ratings according to applicable standards
Composite line post insulators are designed and evaluated according to the relevant electrical and mechanical requirements of their intended applications.
IEC 61952 is an important international standard covering composite line post insulators for AC overhead lines.
IEC 62217 provides general requirements and testing principles for polymeric insulators used in indoor and outdoor applications.
Depending on the project and market, applicable ANSI standards and utility-specific technical specifications may also be considered.
Typical inspection and testing procedures include:
1. Visual inspection of the silicone rubber housing.
2. Dimensional inspection of the complete assembly.
3. Verification of metal fitting dimensions and connections.
4. Mechanical cantilever load testing.
5. Power-frequency withstand voltage testing.
6. Lightning impulse withstand voltage testing.
7. Inspection of material and manufacturing quality.
The applicable test requirements depend on the product design and relevant standard.
Selecting a suitable composite line post insulator involves more than matching the nominal voltage.
Several engineering factors should be evaluated before the final configuration is determined.
Step 1: Identify the Network Voltage
Confirm the nominal system voltage and the highest voltage for equipment.
This distinction is important when selecting between medium and high voltage configurations.
Step 2: Determine the Required Insulation Level
Consider the specified lightning impulse withstand voltage, power-frequency withstand voltage, and required electrical clearances.
Step 3: Calculate Mechanical Loading
Determine the required cantilever load based on conductor arrangement, wind conditions, and the supporting structure.
Step 4: Evaluate Environmental Conditions
Consider pollution severity, humidity, coastal exposure, and other environmental factors affecting external insulation performance.
Step 5: Confirm Mounting Compatibility
Check the base dimensions, mounting holes, connection fittings, and conductor support arrangement to ensure compatibility with the existing equipment.
Q1: What is the main function of a composite line post insulator?
It provides rigid mechanical support for overhead conductors while maintaining the required electrical insulation distance from grounded structures.
Q2: What is the difference between a composite line post insulator and a suspension insulator?
A line post insulator is primarily designed to provide rigid conductor support and withstand cantilever loading. A suspension insulator is generally used in assemblies that carry tensile loads along overhead lines.
Q3: Can the same product design be used for 24kV, 69kV and 72kV systems?
No. Different voltage classes require appropriate insulation dimensions, electrical withstand levels, and mechanical configurations. Each design must be selected according to the corresponding system requirements.
Q4: Why is silicone rubber used for composite line post insulators?
Silicone rubber provides hydrophobic surface properties, weather resistance, and suitable electrical insulation characteristics for outdoor applications.
Q5: Are composite line post insulators suitable for polluted environments?
They can be used in polluted environments when the housing material, shed profile, creepage distance, and insulation level are properly selected for the site’s pollution conditions.
Q6: Can REACON supply customized line post insulators?
Yes. REACON can provide customized configurations based on rated voltage, mechanical loading, creepage distance, mounting dimensions, and customer drawings.
Q7: What information should be provided when requesting a quotation?
Customers can provide the required voltage class, specified cantilever load, creepage distance, installation dimensions, applicable standard, and estimated order quantity.
REACON supplies composite line post insulators for medium and high voltage electrical networks.
With different voltage configurations and structural options, we support overhead line construction, substation installations, and power distribution projects.
Contact REACON for product specifications, technical drawings, customized configurations, and quotations.