REACON
| Availability: | |
|---|---|
| Quantity: | |
The Reliable Single Pole Mounted Transformer for Overhead Power Systems is engineered to provide efficient power distribution, voltage regulation, and stable energy delivery for residential, commercial, and rural electrical grids. Designed for single-pole mounting in aerial networks, this pole mounted transformer features a compact structure, optimized thermal performance, and weather-resistant housing suitable for long-term outdoor operation. With robust insulation, low-loss core technology, and overload protection, this Single Pole Mounted Transformer ensures reliable grid stability, reduced maintenance, and extended service life. It supports applications including public lighting, distribution feeders, renewable power connection, and long-distance rural electrification.
Compact size for easy pole installation
Low loss core improves energy efficiency and reduces operational cost
Weatherproof enclosure designed for harsh outdoor environments
Stable overload capacity and high insulation reliability
Compatible with multiple overhead distribution voltages
The Single Pole Mounted Transformer is commonly applied in:
1. Rural Electrification Projects
Provides reliable power to remote communities.
2. Overhead Distribution Networks
Mounted along feeders for voltage step-down.
3. Public Utility Infrastructure
Supplies energy for street lighting networks.
4. Solar and Wind Energy Integration
Used as a step-down transformer for renewable grid connection.
5. Commercial and Residential Feeder Systems
Ensures stable power for buildings and households.
• Install a pole bracket and secure the transformer mounting points
• Connect high-voltage conductors using appropriate tension clamps
• Attach low-voltage terminals and grounding wire
• Test insulation resistance and verify polarity
• Energize and perform load verification to ensure proper operation

• Manufactured under IEC/IEEE/ANSI transformer standards
• Fully tested for temperature rise, dielectric strength, and short-circuit safety
• Hot-dip galvanized hardware ensures rust-free performance
• Warranty and OEM customization available
Q1: Can the transformer be customized for different voltage ratings?
A1: Yes, voltage, capacity, and terminal configuration can be customized.
Q2: Is maintenance required frequently?
A2: No, the sealed design minimizes maintenance requirements.
Q3: Can it operate in coastal or high-humidity environments?
A3: Yes, the corrosion-resistant materials ensure long-term durability.

REACON Single Pole Mounted Oil Immersed Distribution Transformer is designed for electrical distribution systems where power needs to be stepped down from medium voltage to a usable low-voltage supply. Its pole-mounted configuration makes it suitable for overhead distribution networks, particularly in locations where ground-level transformer installations are impractical or space is limited.
The transformer uses an oil-immersed insulation and cooling system to support continuous electrical operation. Its magnetic core and winding assembly are designed to provide stable voltage transformation while controlling energy losses during normal service.
A weather-resistant tank and outdoor mounting structure allow the unit to operate in different environmental conditions. The compact arrangement also simplifies integration with existing utility poles and overhead line equipment.
REACON provides pole-mounted transformer solutions for residential distribution, rural electrification, commercial facilities, industrial power networks, and distributed energy projects. Different electrical ratings, winding configurations, and structural arrangements can be selected according to project requirements.
The single-pole mounting arrangement is suitable for overhead electrical networks where installation space is restricted. It allows utilities to establish local voltage transformation points without requiring a separate ground-mounted transformer foundation.
The transformer core is designed to provide an effective magnetic path for energy conversion. Appropriate core material selection and winding arrangement help control no-load and load losses, contributing to efficient power distribution.
Insulating oil provides electrical insulation between internal components and helps transfer heat generated during transformer operation. Natural oil circulation and heat dissipation support stable operating temperatures under normal loading conditions.
The protective tank and external surface treatment are designed for outdoor installation. Depending on the selected configuration, corrosion-resistant coatings and suitable structural materials help protect the transformer against moisture, rain, sunlight, and atmospheric exposure.
Primary voltage, secondary voltage, rated capacity, winding material, and terminal arrangements can be selected to match different distribution network designs. This flexibility allows the transformer to serve a variety of utility and industrial projects.
The pole-mounted structure supports integration with overhead line accessories and associated electrical protection devices. Accessible connection points and inspection components facilitate routine maintenance and equipment condition checks.
Parameter | Specification |
Product Type | Pole Mounted Distribution Transformer |
Transformer Construction | Oil Immersed |
Installation Type | Outdoor Pole Mounted |
Number of Phases | Single Phase / Three Phase |
Rated Capacity | Available in multiple kVA ratings |
Primary Voltage | Available according to distribution system requirements |
Secondary Voltage | Configurable according to project requirements |
Rated Frequency | 50Hz / 60Hz |
Core Material | CRGO Silicon Steel / Amorphous Alloy |
Winding Material | Copper / Aluminum |
Cooling Method | ONAN |
Insulating Medium | Electrical Insulating Oil |
Voltage Regulation | Off-Circuit Tap Changer, where specified |
Tank Construction | Outdoor Protective Steel Tank |
Applicable Standard | IEC 60076 / Applicable IEEE Standards |
Magnetic Core
The magnetic core forms the main electromagnetic circuit of the transformer. Grain-oriented silicon steel or amorphous alloy can be selected according to the required efficiency and design specifications.
Its construction influences excitation current, no-load losses, and overall transformer performance.
High Voltage and Low Voltage Windings
The primary winding receives electrical energy from the medium-voltage distribution line, while the secondary winding supplies the required low-voltage output.
Copper or aluminum conductors can be selected depending on electrical design, thermal requirements, and project specifications.
Insulating Oil System
The insulating oil serves two important purposes: electrical insulation and heat transfer. During operation, heat generated inside the windings and core is transferred to the oil and subsequently dissipated through the transformer tank.
Protective Tank and External Structure
The steel tank houses the core, windings, and insulating oil. Its external coating provides protection against environmental exposure, while the mounting structure supports secure attachment to the designated utility pole.
Electrical Bushings and Terminals
High-voltage and low-voltage bushings provide insulated electrical connection points. Their arrangement can be configured to accommodate different overhead line layouts and secondary distribution requirements.
Protective Accessories
Depending on the transformer design, additional accessories may include a pressure relief device, oil level indicator, drain valve, grounding terminal, lightning arrester, fuse cutout, and low-voltage circuit breaker.
In rural distribution networks, pole-mounted transformers provide localized voltage conversion for villages, farms, and remote communities. Their overhead installation helps reduce the need for additional ground-level infrastructure.
The transformer can be installed along residential overhead feeders to supply electricity to homes, apartment areas, and local public facilities.
Factories, workshops, agricultural processing facilities, and commercial buildings may use pole-mounted transformers as part of their local power distribution systems.
Street lighting and other municipal electrical facilities require suitable low-voltage supplies. Pole-mounted transformers can provide the necessary voltage conversion at selected distribution points.
Solar and wind power installations may require transformers to match generated electrical power with the voltage requirements of the connected distribution network. Pole-mounted configurations can be used at suitable grid connection points.
Construction sites, road infrastructure projects, and temporary utility installations can use pole-mounted distribution transformers where a compact overhead power supply arrangement is preferred.
Proper installation is important for electrical safety, equipment performance, and long-term operating reliability.
1. Confirm the transformer capacity, primary voltage, secondary voltage, phase configuration, and connection arrangement according to the electrical system design.
2. Select a suitable utility pole and mounting structure capable of supporting the transformer weight and mechanical loading.
3. Install the mounting brackets and lifting accessories in accordance with the approved installation drawings.
4. Connect the high-voltage side to the overhead distribution network through compatible electrical fittings and protective devices.
5. Connect the low-voltage terminals to the designated distribution circuit and verify the phase arrangement and terminal identification.
6. Complete grounding connections and inspect all electrical joints before commissioning.
7. Conduct the required electrical tests, including insulation resistance, voltage ratio, winding resistance, and other applicable commissioning checks.
Installation and commissioning should be performed by qualified electrical personnel in accordance with local utility regulations.
The transformer is intended for outdoor distribution applications. Its operating configuration should be selected according to the actual environmental and electrical conditions.
Operating Factor | Design Consideration |
Ambient Temperature | According to specified operating conditions |
Installation Environment | Outdoor overhead distribution networks |
Installation Altitude | According to project requirements |
System Frequency | 50Hz / 60Hz |
Cooling | Oil Natural Air Natural (ONAN) |
Installation Structure | Approved pole and mounting arrangement |
Environmental Exposure | Rain, humidity, sunlight, and atmospheric pollution |
REACON places emphasis on electrical performance, insulation integrity, and structural quality throughout transformer manufacturing.
The inspection and testing process can include:
• Winding resistance measurement to check electrical continuity and winding condition.
• Voltage ratio and polarity verification to confirm the specified transformation relationship.
• No-load loss and excitation current measurement to evaluate magnetic core performance.
• Load loss and impedance measurement to assess electrical characteristics.
• Applied voltage and induced voltage tests to examine insulation performance.
• Insulating oil and tank leakage inspections to evaluate sealing integrity.
• Appearance and dimensional inspections to verify the finished assembly.
Routine testing is carried out according to the applicable product standards and agreed technical specifications.
Q1: What is a single pole mounted distribution transformer?
A single pole mounted distribution transformer is an electrical unit installed on a utility pole to reduce medium-voltage electricity to a lower voltage suitable for local consumption. It is commonly used in overhead distribution networks.
Q2: What is the difference between a pole-mounted transformer and a pad-mounted transformer?
A pole-mounted transformer is installed above ground on a utility pole, while a pad-mounted transformer is installed at ground level on a concrete foundation or equipment pad. Pole-mounted designs are commonly selected for overhead distribution systems with limited ground space.
Q3: Can the transformer be manufactured with different voltage ratings?
Yes. Primary and secondary voltage ratings can be configured according to the distribution network and project specifications.
Q4: Is copper or aluminum winding available?
Both copper and aluminum winding options can be considered according to the required electrical performance, design conditions, and customer specifications.
Q5: What cooling method is used in an oil-immersed pole-mounted transformer?
ONAN cooling uses natural oil circulation and natural air cooling. Heat generated inside the transformer is transferred through the insulating oil to the external tank surface and dissipated into the surrounding air.
Q6: Can the transformer operate in humid and coastal environments?
Yes, suitable outdoor configurations can be selected with protective surface coatings and appropriate structural materials to withstand humid and corrosive environments.
Q7: Which international standard is applicable to distribution transformers?
IEC 60076 is the main international standard series covering power transformers, including general requirements, temperature rise, insulation, and testing. Applicable IEEE and ANSI standards can also be followed for projects requiring North American specifications.
REACON specializes in the development and supply of electrical power transmission and distribution equipment for utility and industrial applications.
Our product portfolio covers pole-mounted transformers, oil-immersed transformers, dry-type transformers, surge arresters, fuse cutouts, disconnect switches, insulators, and overhead line fittings.
We support different electrical configurations and project-specific requirements, providing technical assistance and product solutions for power distribution applications worldwide.
Contact REACON for technical specifications, product drawings, and quotations for pole-mounted distribution transformers.