REACON SCB Series Three Phase Epoxy Resin Cast Dry Type Transformer is developed for medium-voltage electrical distribution systems in commercial, industrial, and public infrastructure projects. Available in SCB10 and SCB11 configurations, this transformer series provides voltage conversion solutions for networks operating at different voltage levels, including 10kV and 20kV applications.
Unlike oil-filled transformers, the cast-resin design uses solid epoxy insulation around the windings. This construction eliminates the need for insulating oil and reduces concerns associated with oil leakage. It is particularly suitable for indoor substations, electrical distribution rooms, and installations where fire safety and environmental protection are important considerations.
The transformer consists of a laminated silicon steel core, high-voltage windings, low-voltage windings, an insulation system, and supporting structural components. The high-voltage coils are encapsulated with epoxy resin, forming an insulated structure that protects the winding conductors from external moisture and environmental contaminants.
Depending on the required capacity and operating conditions, the transformer can be equipped with temperature monitoring devices, cooling fans, protective enclosures, and other electrical accessories.
REACON offers SCB series dry-type transformer solutions for distribution networks requiring different voltage ratings, load capacities, and installation configurations.
The SCB10 and SCB11 models are designed for different electrical distribution requirements. Their main differences involve series designation, voltage configuration, and applicable operating specifications.
Item | SCB10 Series | SCB11 Series |
Product Type | Cast Resin Dry Type Transformer | Cast Resin Dry Type Transformer |
Featured Voltage Rating | 20kV | 10kV |
Phase | Three Phase | Three Phase |
Insulation | Epoxy Resin Cast | Epoxy Resin Cast |
Cooling | AN / Optional AF | AN / Optional AF |
Typical Application | 20kV Distribution Networks | 10kV Distribution Networks |
Installation | Indoor Substations and Electrical Rooms | Indoor Substations and Electrical Rooms |
Both series can be selected according to the voltage level, transformer capacity, efficiency requirements, and electrical characteristics of the distribution system.
Parameter | Specification |
Product Name | Epoxy Resin Cast Dry Type Transformer |
Product Series | SCB10 / SCB11 |
Number of Phases | Three Phase |
Rated Capacity | 30–2500 kVA |
Primary Voltage | 10kV / 20kV and other available ratings |
Secondary Voltage | Configurable according to project requirements |
Rated Frequency | 50Hz / 60Hz |
Insulation Type | Epoxy Resin Cast Insulation |
Core Material | Cold-Rolled Grain-Oriented Silicon Steel |
Winding Material | opper / Aluminum |
Cooling Method | AN / AF |
Connection Group | Dyn11 / Yyn0 or specified configuration |
Tap Changer | Off-Circuit Tap Changer |
Insulation Class | F / H, according to design |
Enclosure Protection | IP00 / IP20 / IP23 options |
Installation | Indoor / Outdoor with suitable enclosure |
Applicable Standards | IEC 60076-11, GB/T 10228 and relevant project specifications |
The transformer core is manufactured from electrical silicon steel sheets assembled into a magnetic circuit. The core structure is designed to provide a stable magnetic path while controlling excitation current and no-load losses.
The core assembly is mechanically secured to maintain structural stability during transportation and operation.
The high-voltage windings are encapsulated with epoxy resin through a controlled casting process. This creates a solid insulation layer around the conductors and helps prevent direct exposure to moisture, dust, and other environmental contaminants.
Vacuum casting technology can be used to reduce air bubbles and improve insulation consistency within the winding structure.
The low-voltage winding is generally manufactured using copper or aluminum foil, depending on the transformer design.
Its winding arrangement is developed to distribute electrical current and mechanical forces appropriately, supporting stable operation under normal loading conditions.
The transformer uses air as the cooling medium.
Under AN cooling, heat is transferred from the windings and core to the surrounding air through natural convection. For installations requiring additional thermal capacity, AF cooling can be provided through forced-air fans.
The cooling configuration is selected according to rated capacity and operating conditions.
Temperature sensors can be installed to monitor the operating temperature of the windings. A temperature controller can provide temperature indication, alarm signals, and automatic fan control.
Additional protection arrangements can be selected according to the electrical installation requirements.
The epoxy resin insulation system eliminates transformer oil, reducing the possibility of oil leakage and simplifying the requirements for oil-related inspection and handling.
This makes the transformer suitable for buildings and electrical rooms where liquid insulation is not preferred.
The resin casting process provides a solid insulating layer around the high-voltage winding. This structure helps maintain electrical insulation under specified operating conditions and offers resistance to moisture and environmental contaminants.
The absence of insulating oil removes the risk of oil leakage and oil-related fires. The epoxy resin insulation system also provides flame-retardant characteristics according to the selected material specification.
The winding structure and supporting components are designed to withstand electrical and mechanical stresses during normal operation and specified short-circuit conditions.
Natural air cooling is suitable for standard operating conditions. Forced-air cooling can be incorporated when additional heat dissipation is required.
The transformer can be supplied with different enclosure structures, terminal arrangements, and monitoring accessories to suit indoor substations, industrial electrical rooms, and other distribution installations.
Component | Description |
Silicon Steel Core | Provides the magnetic circuit for electrical energy conversion. |
High-Voltage Winding | Receives input power from the medium-voltage network. |
Low-Voltage Winding | Supplies transformed electrical power to the load side. |
Epoxy Resin Insulation | Encapsulates the winding structure and provides solid electrical insulation. |
Core Clamping Structure | Secures the magnetic core and maintains mechanical stability. |
Cooling Fans | Provide additional airflow for forced-air cooling configurations. |
Temperature Controller | Monitors winding temperature and controls cooling fans when configured. |
Temperature Sensors | Detect operating temperatures within the winding assembly. |
Protective Enclosure | Provides mechanical protection against external contact and environmental exposure |
High and Low Voltage Terminals | Connect the transformer to the corresponding electrical circuits. |
Optional accessories can be selected according to the installation design and project requirements.
The 10kV and 20kV configurations can be used in urban distribution systems to transform medium-voltage electricity for residential and commercial consumption.
Typical installations include indoor substations, distribution rooms, and compact electrical facilities.
Manufacturing facilities require suitable transformer capacity to supply production machinery, motors, automation equipment, and auxiliary electrical systems.
The SCB series provides voltage transformation for industrial distribution networks where oil-free insulation is preferred.
Shopping malls, office buildings, hotels, and large commercial complexes commonly use dry-type transformers in dedicated electrical rooms.
The cast-resin construction is suitable for installations where fire protection and reduced oil-related environmental risks are important.
Hospitals, schools, airports, railway stations, and other public facilities require properly designed electrical distribution equipment.
Dry-type transformers can be incorporated into these facilities as part of their medium-voltage and low-voltage power distribution systems.
Underground electrical rooms, subway stations, tunnels, and underground parking facilities may use cast-resin transformers as part of their local power supply infrastructure.
Their oil-free construction helps reduce concerns associated with liquid insulation in enclosed installations.
Dry-type distribution transformers can be used in suitable solar power facilities, energy storage installations, and auxiliary power systems where the required voltage and capacity match the transformer design.
Selecting the correct SCB series transformer begins with evaluating the electrical requirements of the installation.
First, determine the incoming grid voltage and the required output voltage. A 10kV or 20kV primary configuration should be selected according to the existing distribution network.
Next, calculate the connected load and required transformer capacity. Consider the operating load, expected load growth, starting current of large motors, and possible future expansion.
The winding material, connection group, cooling method, insulation class, and enclosure protection should then be selected according to the electrical design and installation environment.
During installation, the transformer should be positioned on a suitable foundation with sufficient clearance for ventilation, inspection, and maintenance. High-voltage and low-voltage connections must follow the specified wiring arrangement.
Before commissioning, electrical inspections and applicable factory or site tests should be completed. These may include insulation resistance measurement, winding resistance measurement, voltage ratio verification, and protection system checks.
During service, regular inspection of electrical connections, ventilation passages, temperature readings, and enclosure conditions helps maintain reliable operation.
REACON applies manufacturing and inspection procedures to the production of epoxy resin cast dry-type transformers.
The manufacturing process includes core lamination and assembly, winding production, resin casting, insulation curing, active-part assembly, and final electrical inspection.
Relevant quality inspection and testing procedures include:
• Winding resistance measurement
• Voltage ratio verification
• Vector group verification
• No-load loss and no-load current measurement
• Load loss and impedance voltage measurement
• Applied voltage withstand test
• Induced voltage withstand test
• Partial discharge measurement
• Temperature rise test when specified
• Insulation system and resin casting inspection
Routine tests are performed according to the applicable product standards and project requirements before delivery.
Additional inspections and special tests can be arranged for projects with specific technical or contractual requirements.
Q1: What is the difference between SCB10 and SCB11 dry-type transformers?
SCB10 and SCB11 are different cast-resin dry-type transformer series. Their designation and electrical performance specifications may differ depending on the applicable design standard. The actual loss values and efficiency requirements should be evaluated using the corresponding technical datasheet.
Q2: Can this transformer be used in both 10kV and 20kV distribution systems?
Yes. Different voltage configurations are available within the SCB series. The 10kV and 20kV versions are selected according to the incoming grid voltage and the electrical requirements of the installation.
Q3: What is the difference between a cast-resin transformer and an oil-immersed transformer?
A cast-resin transformer uses solid epoxy resin to insulate its windings and uses air for cooling. An oil-immersed transformer uses insulating liquid for both insulation and heat transfer. Cast-resin designs are commonly selected for indoor installations where oil-free construction is preferred.
Q4: Is the SCB series suitable for indoor installation?
Yes. SCB series transformers are commonly installed in indoor substations, electrical distribution rooms, commercial buildings, and industrial facilities. The enclosure and ventilation arrangement should be selected according to the installation environment.
Q5: What cooling methods are available?
AN natural air cooling is commonly used. AF forced-air cooling can also be provided through cooling fans to increase heat dissipation when required.
Q6: Can copper or aluminum windings be selected?
Yes. Copper and aluminum winding configurations can be considered according to the required electrical performance, project specifications, and purchasing requirements.
Q7: Does the transformer require regular oil replacement?
No. The SCB series is a dry-type transformer and does not use insulating oil. Routine inspection is still required for electrical connections, ventilation, temperature monitoring devices, and other installed components.
Q8: Can the transformer be equipped with an outdoor enclosure?
Yes. A suitable protective enclosure can be provided for installations requiring additional protection against dust, external contact, and environmental exposure. The enclosure design should match the actual outdoor operating conditions.
Q9: What information is needed to select an SCB series transformer?
The main selection information includes rated capacity, primary voltage, secondary voltage, frequency, winding material, connection group, cooling method, and installation environment.
REACON supplies electrical distribution equipment for utility, industrial, and infrastructure projects.
Our transformer product range includes epoxy resin cast dry-type transformers and oil-immersed distribution transformers for different electrical applications.
For SCB10 and SCB11 transformer inquiries, REACON can assist with voltage selection, capacity configuration, technical specifications, and project-based product solutions.