The 22kV Composite Polymer Fuse Cutout is designed for modern overhead distribution networks requiring enhanced safety, high mechanical strength, and excellent weather resistance. Using a lightweight polymer body combined with corrosion-resistant metal hardware, it delivers superior performance in polluted, coastal, and high-humidity environments.
The Power Protection Cover is a high-quality protective housing specially designed to shield electrical equipment from enviro
lightweight, unbreakable, hydrophobic, resistant ozone UV radiations, resistant earthquake
Long rod suspension insulator ?Composite insulators for high voltage overhead power transmission line application
For rated voltage up to 36 kV power transmission lines supporting, suspending and insulation.
Ratings: Up to 36kV.
Standards: IEC 61952:2008,ANSI,etc
Composite Insulator for AC Power Distribution System
Features: Secure and reliable operation on high mechanical strength. Compact design and light in weight which is convenient for transportation. Good anti-vibration capability. Good anti-moisture capability. Good electric performances Strong anti-pollution falshover ability. High anti-aging performances which is perfect for utilization under conditions of high altitude. Easy for maintenance.

Lightweight polymer housing reduces installation difficulty
Superior resistance to UV, corrosion, moisture, and salt fog
High mechanical strength and impact resistance
Visible break design enhances operational safety
Hot dip galvanized hardware ensures long service life
Stable performance in polluted environments
Quick fuse replacement minimizes outage time
Excellent hydrophobicity keeps insulation performance stable
Strong arc-extinguishing capability
Compatible with all 22kV overhead line systems
Long rod Composite insulators up to 500kV.
Pin Composite insulator up to 36kV.
Post Composite insulator up to 252kV.
Line post Composite insulator up to 36kV.
22kV overhead distribution lines
Urban, rural & industrial distribution networks
Pole-mounted transformer primary protection
22kV branch line isolation
High-humidity, coastal, and polluted areas
Wind farm and solar farm overhead feeders
• Mount the fuse cutout on a pole using galvanized brackets and stainless straps.
• Connect incoming and outgoing conductors with proper torque.
• Insert the polymer fuse tube and lock the drop-out assembly.
• Upon fault occurrence, the fuse link melts and the tube drops visibly.
• Replace the fuse link after confirming isolation.
1)The silicone rubber housing taken shape by whole injection has good hydrophobicity, drophobicity migration and soil resistance, as well as excellent electrical insulation roperties and aging resistance, which could prevent effectively those accidents of pollution flashovers so as to ensure the safe running of high voltage transmission lines.
2)The modified ECR fiberglass reinforced epoxy resin rod is used as it has good resistance to high temperature, stress corrosion &acid attack, as well as fine damping action, high tensile strength( >1200Mpa ) and resistance to creep and fatigue failure, which effectively ensure the internal insulation quality and mechanical strength of insulators.
3)End fittings are crimped onto fiberglass rod with voice-operated displacement type crimper , The insulators with this crimping technique have high mechanical strength and small dispersion.
4)The connection location between end fittings & rods is fused with sheds housing by the overall high tempera- ture vulcanized silicone rubber injection molding as it could minimize the interface.
5)The internal radial multi-seal structure effectively guarantees a long-term reliability of seal around the connection between end fittings & rods.

Complies with IEC, IEEE, and utility standard
Every unit tested for dielectric, mechanical & thermal performance
Polymer housing with long-term UV stability
Hot-dip galvanized hardware for corrosion protection
Strict inspection on fuse link, contact pressure & drop-out reliability
1 Applicable stardand:IEC,ANSI,GB and other international standard
2 Normal colour of the composite insulator:red,gray and white.
3 Special design according customer's requirement.
| Main Technical Parameter | |||||||
| Model | Rated voltage(KV) | Specified Mechanical load(KN) | Spacing H (mm) | Arcing distance (>mm)) | Minimum Creepage distance | Lightning impulse Withstand voltage (>=KVp) | Wet power frequency withstand voltage (>=KVr.m.s.) |
| FPW-12/5 | 12 | 5 | 248 | 195 | 315 | 100 | 45 |
| FPW-12/5 | 12 | 5 | 228 | 195 | 315 | 100 | 45 |
| FPW-15/5 | 15 | 5 | 268 | 215 | 450 | 120 | 50 |
| FPW-15/5 | 15 | 5 | 248 | 215 | 450 | 120 | 50 |
| FPW-24/8 | 24 | 5 | 308 | 250 | 480 | 150 | 60 |
| FPW-24/8 | 24 | 5 | 288 | 250 | 480 | 150 | 60 |
| FPW-36/5 | 36 | 5 | 413 | 340 | 900 | 180 | 80 |
| FPW-36/5 | 36 | 5 | 393 | 340 | 900 | 180 | 80 |
Q1: What is the main advantage of polymer over porcelain?
A1: It is lighter, more impact-resistant, and more weather-resistant.
Q2: Can this 22kV cutout be used in coastal or polluted regions?
A2: Yes, its hydrophobic polymer housing performs exceptionally well in such environments.
Q3: Is it easy to replace the fuse link?
A3: Yes, the drop-out design allows quick and safe replacement.
Q4: What type of systems is it compatible with?
A4: It is compatible with all standard 22kV overhead distribution structures.