It is worth mentioning that we use ANCHORING cement (por rok) produced by CGM INC in the United States, and all iron parts on the product have been hot-dip galvanized, with a galvanized layer of over 86u and good corrosion resistance.
| Availability: | |
|---|---|
| Quantity: | |
The 11–15kV High Voltage Electrical Distribution Standard Fuse Cutout is an outdoor protection device designed for overhead power distribution systems. This high voltage fuse cutout provides reliable protection against overloads and short circuits by safely disconnecting faulty sections of the line. With a visible drop-out operation, the 11–15kV electrical distribution standard fuse cutout improves system safety and allows maintenance personnel to quickly identify fault locations.

Reliable protection for 11–15kV power distribution systems
Visible drop-out design improves maintenance safety
Standard design suitable for utility-grade applications
Stable electrical performance under outdoor conditions
Effective overload and short-circuit interruption
Easy fuse link replacement reduces downtime
Strong mechanical structure for long service life
Widely used in urban and rural distribution networks
| Rated voltage(KV) | Rated current(A) | Rated interrupting current(KA) | Lightning impulse withstand voltage to ground (BIL KV) | Minimum power frequency withstand dry voltage to ground (KV) | Minimum creepage distance(mm) |
| 11-15 | 100/200 | 12 | 110 | 42 | 220 |
| 11-15 | 100/200 | 12 | 125 | 50 | 320 |
Overhead electrical distribution lines rated at 11–15kV
Pole-mounted transformer protection
Branch line protection in distribution networks
Utility power distribution systems
Areas requiring visible isolation for maintenance safety
• Mount the 11–15kV high voltage electrical distribution standard fuse cutout on the utility pole using appropriate hardware.
• Install the correct fuse link according to system voltage and current rating.
• Connect the incoming and outgoing conductors securely to the fuse terminals.
• Ensure proper alignment to allow smooth drop-out operation during faults.
• Perform inspection and testing before putting into service.
Manufactured with high-quality insulating and metal components
Designed to meet electrical distribution standards
Each unit tested for mechanical and electrical reliability
Stable quality for long-term outdoor operation
Consistent performance for utility applications
Q1: What voltage range is this fuse cutout designed for?
A1: It is designed for 11–15kV high voltage electrical distribution systems.
Q2: Is this fuse cutout suitable for outdoor installation?
A2: Yes, it is designed specifically for outdoor overhead line applications.
Q3: Does the fuse cutout provide visible fault indication?
A3: Yes, the drop-out mechanism clearly indicates fault conditions.
Q4: Is maintenance complicated?
A4: No, fuse link replacement is simple and efficient.
Q5: Where is this fuse cutout commonly used?
A5: Overhead distribution lines, transformers, and branch circuit protection.