REACON
| Availability: | |
|---|---|
| Quantity: | |
Pole-mounted distribution networks often require equipment capable of both overcurrent protection and load switching. A load break fuse cutout combines these functions, allowing operators to disconnect circuits under load while maintaining system protection capabilities.
The Reacon 36kV Porcelain Load Break Fuse Cutout is designed for medium-voltage overhead networks where switching and sectionalizing operations are required. The porcelain housing provides mechanical support and insulation performance for outdoor utility installations.
This product is commonly used in distribution feeders, transformer protection schemes, and pole-mounted switching locations throughout utility power systems.
Porcelain insulated construction
Rated for 36kV applications
Load break switching capability
Suitable for pole-mounted installations
Supports circuit sectionalizing operations
Compatible with overhead distribution systems
Designed for outdoor service environments
Available in multiple current ratings
Pole-mounted switching points
Distribution feeder sectionalizing
Utility infrastructure projects
Transformer protection installations
Rural electrification systems
Overhead distribution networks
Unlike standard fuse cutouts that primarily provide fault protection, a load break fuse cutout is designed to allow switching operations while the circuit remains energized under normal load conditions.
Isolate feeder sections
Support maintenance activities
Improve operational flexibility
Facilitate distribution network management
Because of these functions, load break cutouts are commonly installed at strategic switching points in utility systems.
| Rated Voltage (kV) | BIL (kV) | A (mm) | B (mm) | C (mm) | D (mm) | E (mm) | F (mm) | Leakage Distance (mm) | Weight (kg) |
| 12(15) | 125 | 331.4 | 169.3 | 202.4 | 462.8 | 124.9 | 412.8 | 325.1 | 6.58 |
| 24(27) | 125 | 341.4 | 179.3 | 202.4 | 462.8 | 134.9 | 412.8 | 325.1 | 6.58 |
| 24(27) | 150 | 341.4 | 179.3 | 202.4 | 462.8 | 134.9 | 412.8 | 457.2 | 9.08 |
| 24(33) | 200 | 435.1 | 187.5 | 261.1 | 548.4 | 165.1 | 522.2 | 665.5 | 10.1 |
| 24(36) | 200* | 435.1 | 187.5 | 261.1 | 548.4 | 165.1 | 522.2 | 769.6 | 10.4 |
| Item | Description |
| Product Name | 36kV Porcelain Load Break Fuse Cutout |
| Rated Voltage | 36kV |
| Insulator Material | Porcelain |
| Type | Load Break Fuse Cutout |
| Installation | Pole Mounted |
| Application | Switching and Protection |
| Service Environment | Outdoor |
| OEM Service | Available |
Q1: What is a load break fuse cutout used for?
A1: It provides both overcurrent protection and load switching capability in overhead distribution systems.
Q2: How is it different from a standard fuse cutout?
A2: A load break fuse cutout can be operated under normal load conditions, while standard cutouts are primarily intended for fault protection and isolation.
Q3: Why use porcelain insulation?
A3: Porcelain is widely used in outdoor electrical equipment for its insulation and mechanical performance.
Q4: Can it be installed on utility poles?
A4: Yes. It is specifically designed for pole-mounted distribution applications.
Q5: Does Reacon offer different ratings?
A5: Yes. Various voltage and current configurations can be supplied according to project requirements.