REACON
| Availability: | |
|---|---|
| Quantity: | |
Medium-voltage electrical networks require switching devices that allow sections of a circuit to be safely isolated during maintenance, inspection, or equipment replacement. A disconnect switch provides a visible open point, helping operators verify that a circuit has been separated from the power source before work begins.
The Reacon 38kV Outdoor Disconnect Switch is designed for substation and distribution network applications where manual circuit isolation is required. The switch provides a visible break in the circuit and is commonly installed on utility structures, substation frameworks, and medium-voltage distribution systems.
Manufactured for outdoor environments, the switch is suitable for utility infrastructure, industrial power facilities, and renewable energy projects.
Rated for 38kV applications
Outdoor installation design
Visible circuit isolation function
Suitable for medium-voltage systems
Compatible with utility distribution networks
Supports maintenance and operational switching
Designed for long-term outdoor service
Available in multiple mounting configurations

| KV | Amperes | (kA/Is) | Dimensions | |||||
| Nominal voltage | Maximum voltage | BIL | Nominal Current | Transient Current | A | B | C | D |
| (mm) | ||||||||
| 13.8 | 15 | 95 | 200/630 | 16 | 305 | 270 | 580 | 186 |
| 630 | 25 | 305 | 313 | 595 | 230 | |||
| 110 | 200/630 | 16 | 381 | 270 | 650 | 186 | ||
| 630 | 25 | 381 | 313 | 670 | 230 | |||
Utility substations
Distribution feeder circuits
Overhead power networks
Industrial electrical facilities
Renewable energy substations
Medium-voltage switching systems
Unlike protective devices such as fuse cutouts or circuit breakers, a disconnect switch is primarily used to establish a visible open point in the electrical circuit.
Verify circuit isolation
Improve maintenance safety procedures
Facilitate equipment replacement
Support planned network maintenance
Simplify operational switching activities
For this reason, disconnect switches remain an important component in substation and distribution system design.
| Product Name | 38kV Outdoor Disconnect Switch |
| Rated Voltage | 38kV |
| Switch Type | Air Break Disconnect Switch |
| Application | Circuit Isolation |
| Installation | Outdoor |
| Service Environment | Utility and Industrial Systems |
| OEM Service | Available |
Reacon manufactures disconnect switches, fuse cutouts, surge arresters, insulators, grounding accessories, and transmission line hardware for utility and industrial power infrastructure projects. Customized production is available according to technical drawings and project requirements.
Q1: What is a 38kV disconnect switch used for?
A1: It is used to isolate electrical circuits and provide a visible open point for maintenance and operational purposes.
Q2: Can the switch interrupt fault current?
A2: Disconnect switches are primarily intended for isolation functions. System protection requirements should be determined according to project specifications.
Q3: Is the switch suitable for substations?
A3: Yes. It is commonly installed in utility substations and medium-voltage distribution systems.
Q4: Why is a visible break important?
A4: A visible break helps operators confirm that the circuit has been isolated before maintenance activities begin.
Q5: Does Reacon offer customized configurations?
A5: Yes. Customized mounting arrangements and project-specific designs can be supplied.