REACON
| Availability: | |
|---|---|
| Quantity: | |
Connecting copper conductors to aluminum conductors requires careful consideration of both electrical performance and material compatibility. Direct connections between dissimilar metals may accelerate galvanic corrosion, particularly in outdoor environments exposed to moisture and temperature changes.
The CAPG C Aluminum Copper Bimetallic PG Clamp is designed to provide a transition connection between copper and aluminum conductors while maintaining stable conductivity and mechanical holding strength. Its bimetallic construction helps reduce contact issues associated with mixed-metal conductor installations.
The clamp is widely used in distribution and transmission projects where conductor materials differ within the same electrical network.
Designed for copper to aluminum conductor connection
Bimetallic construction
Parallel groove clamping structure
Stable electrical contact performance
Suitable for overhead line installations
Strong mechanical holding capability
Adapted to outdoor utility environments
Easy field installation
The clamp is commonly installed in:
Overhead distribution networks
Utility power line projects
Conductor transition connections
Electrical network upgrades
Transmission and distribution systems
Industrial power infrastructure
In mixed-conductor systems, using a dedicated bimetallic connection fitting helps improve connection reliability. The transition design between aluminum and copper materials assists in reducing galvanic effects that can occur when different conductor materials are joined directly.
This makes the clamp a practical choice for utility networks where conductor compatibility and long-term connection stability are important considerations.
| Product Name | CAPG C Aluminum Copper Bimetallic PG Clamp |
| Product Type | Parallel Groove Clamp |
| Material | Aluminum and Copper |
| Application | Conductor Connection |
| Installation | Overhead Power Lines |
| Surface Treatment | Corrosion Resistant |
| OEM Service | Available |
Overhead power distribution lines
Aluminum conductor to copper conductor connections
Utility pole-mounted power systems
Power line branching and tapping connections
Outdoor electrical bonding applications
Select the correct CAPG-C aluminum copper bimetallic PG clamp according to conductor size.
Place the aluminum and copper conductors into the parallel grooves.
Tighten the bolts evenly to ensure firm mechanical and electrical contact.
Check contact surfaces to confirm proper alignment and pressure.
Perform final inspection before energizing the overhead line.
High-quality aluminum and copper materials
Precision machining for accurate groove dimensions
Anti-corrosion surface treatment
Electrical conductivity and mechanical strength testing
Strict final inspection before shipment
Reacon manufactures conductor connection fittings, transmission hardware, and electrical power accessories for utility and infrastructure projects worldwide. We provide stable production quality, technical support, and customized manufacturing according to customer drawings and specifications.


Q1: What is a CAPG C PG clamp used for?
A1: It is used to connect copper conductors and aluminum conductors in overhead electrical systems.
Q2: Why is a bimetallic design important?
A2: A bimetallic structure helps improve compatibility between different conductor materials and reduces the risk of galvanic corrosion.
Q3: Can the clamp be used outdoors?
A3: Yes. It is designed for outdoor utility and power distribution applications.
Q4: What conductor types can be connected?
A4: The clamp is intended for copper-to-aluminum conductor transition connections.
Q5: Does Reacon support customized production?
A5: Yes. Customized dimensions and specifications can be manufactured according to project requirements.
The CAPG-C Bimetallic Parallel Groove Clamp is designed with a parallel groove structure that accommodates two conductors within corresponding contact channels. Its mechanical fastening arrangement uses bolted pressure to hold the conductors in position and establish an electrical connection.
Unlike conventional single-material connectors, a bimetallic PG clamp incorporates different conductive materials within one connector assembly. This configuration is particularly important when aluminum conductors need to be connected to copper conductors or copper electrical terminals.
The design focuses on three important aspects: conductor positioning, contact interface compatibility, and mechanical fastening stability.
1. Parallel Groove Configuration
The grooved contact surfaces provide designated positions for the conductors. This arrangement helps maintain alignment during installation and creates a defined contact area between the connector and the conductors.
2. Bolted Fastening Assembly
Bolts provide the mechanical pressure required to secure the conductors. Proper tightening helps maintain the connection position and reduces the possibility of conductor movement caused by external mechanical influences.
3. Bimetallic Contact Interface
The aluminum and copper components are incorporated into the connector to accommodate connections involving dissimilar conductor materials. The transition interface is an important part of the overall electrical connection design.
4. Compact Connector Arrangement
The parallel groove structure allows the connector to be installed at designated connection points in overhead electrical networks without requiring a complicated supporting assembly.
Connecting aluminum and copper conductors requires attention to material compatibility. When two dissimilar metals come into direct contact in the presence of moisture or other environmental conditions, galvanic corrosion may occur.
This process can gradually affect the contact interface, increase connection resistance, and influence the long-term performance of electrical joints.
The CAPG-C bimetallic PG clamp addresses this issue through its aluminum-copper transition construction.
For the commonly configured aluminum body with a tinned copper insert, the copper contact component provides a suitable interface for copper conductors, while the aluminum section accommodates the corresponding aluminum conductor connection.
The tin coating on the copper contact area also serves as a protective layer for the metal surface.
• Improved Contact Stability: Compatible contact surfaces help maintain the electrical connection under normal operating conditions.
• Electrical Continuity: The conductive interface supports current transfer between connected conductors.
• Outdoor Adaptability: Suitable material combinations and protective treatments help the connector withstand normal outdoor exposure.
• Long-Term Connection Reliability: Correct material selection helps reduce deterioration risks at conductor transition points.
For projects involving coastal areas, industrial environments, or locations with high humidity, buyers should also consider the required corrosion protection level when selecting the connector.
In addition to overhead distribution lines, aluminum-copper bimetallic connectors are used in electrical installations where conductors and equipment terminals have different material compositions.
These connection points require appropriate conductor hardware to establish electrical continuity while maintaining mechanical stability.
1. Substation Busbar Connections
Electrical substations may contain aluminum busbars, copper terminals, and different types of connecting conductors.
A suitable bimetallic connection fitting can be incorporated into the connection arrangement when aluminum and copper components need to be electrically connected.
2. Transformer Terminal Connections
Distribution transformers and associated electrical equipment may have terminals made from materials different from the connected overhead conductors.
The appropriate bimetallic connector helps provide a transition between the conductor and the equipment connection point.
3. Distribution Equipment Upgrading
When existing electrical installations are upgraded, replacement equipment may have different conductor materials or terminal configurations.
Bimetallic connection hardware can help accommodate these material differences without unnecessarily changing the entire conductor arrangement.
4. Industrial Electrical Infrastructure
Industrial facilities often contain different types of electrical conductors, busbars, and connection terminals.
Suitable bimetallic connectors can be incorporated into electrical distribution installations where copper and aluminum components need to be connected.
Overhead power line fittings are continuously exposed to environmental conditions that can affect their electrical and mechanical performance.
Rainfall, humidity, temperature fluctuations, airborne pollutants, and salt-containing air may contribute to surface deterioration and corrosion over time.
For this reason, connector selection should consider both the electrical characteristics of the conductor and the environmental conditions at the installation site.
The CAPG-C bimetallic PG clamp can be specified for outdoor utility applications where copper-to-aluminum conductor connections are required.
Coastal Installations
Salt-containing air can accelerate corrosion of exposed metal components. Appropriate material protection and surface treatment should be considered for coastal distribution projects.
High-Humidity Regions
Moisture may contribute to corrosion at metal contact interfaces. A suitable bimetallic connection arrangement helps address the material compatibility issue associated with aluminum and copper conductors.
Industrial Areas
Airborne contaminants and chemical pollutants may affect exposed electrical fittings. Buyers should specify the environmental protection requirements when requesting customized products.
Temperature Variation
Outdoor connectors experience temperature changes during normal operation. Proper conductor compatibility, contact pressure, and installation quality are important for maintaining connection stability.
A conductor connector must provide both electrical continuity and sufficient mechanical holding capability.
Even when the conductive materials are suitable, poor conductor positioning or incorrect bolt tightening may affect the quality of the connection.
The performance of a parallel groove clamp therefore depends on the combined effect of its contact structure, fastening components, material properties, and installation quality.
Important Performance Considerations
• Contact Area: The contact surfaces should match the intended conductor configuration to establish an appropriate electrical interface.
• Fastening Pressure: Bolts should be tightened according to the manufacturer’s recommended torque requirements.
• Conductor Retention: The groove arrangement and fastening assembly should provide adequate mechanical holding capability.
• Contact Resistance: Proper material compatibility and installation help maintain suitable electrical contact conditions.
• Thermal Performance: The connector should be selected according to the electrical load and applicable operating requirements.
These factors are particularly important for permanent conductor connections in distribution and transmission infrastructure.
The CAPG-C bimetallic PG clamp can be considered for different power infrastructure projects involving aluminum-to-copper conductor transitions.
Depending on the selected configuration, typical project applications include:
Urban Power Distribution Renovation
Urban electrical networks often require the replacement of aging conductors and the upgrading of distribution equipment. Bimetallic connectors can be used where existing aluminum lines need to interface with copper conductors or equipment terminals.
Rural Electrification Projects
Rural distribution networks may contain different generations of electrical equipment and conductor materials. Appropriate transition connectors help accommodate mixed-material connection requirements during network expansion.
Industrial Power Supply Systems
Factories, manufacturing facilities, and industrial parks require reliable connections between distribution conductors and electrical equipment. Bimetallic PG clamps can be incorporated into suitable conductor connection arrangements.
Renewable Energy Infrastructure
Solar power stations and wind power facilities may include different conductor materials within their collection and distribution systems. Bimetallic connection hardware can be specified where the electrical design requires copper-to-aluminum transitions.
Transmission and Distribution Equipment Installation
Utility contractors may use bimetallic conductor fittings during line construction, equipment installation, and electrical network modification projects.
Correct installation is essential for achieving reliable electrical and mechanical connections.
Before installing a CAPG-C bimetallic PG clamp, technicians should check the conductor specifications, connector configuration, contact surfaces, and required fastening conditions.
Installation Preparation
1. Verify the conductor materials and cross-sectional dimensions.
2. Confirm that the selected connector is suitable for the main conductor and branch conductor combination.
3. Inspect the contact surfaces and fastening components for visible damage or contamination.
4. Prepare the installation tools according to the manufacturer’s instructions.
5. Confirm that the installation location provides sufficient working space and mechanical support.
Installation Procedure
1. Identify the aluminum and copper connection positions according to the connector design.
2. Place each conductor into its corresponding groove or contact section.
3. Ensure that the conductors are correctly positioned and properly seated.
4. Tighten the fastening bolts evenly according to the specified torque.
5. Inspect the assembled connection for alignment and mechanical security.
6. Complete the required electrical and mechanical inspections before the circuit is put into service.
For energized electrical installations, all work must follow the applicable utility safety procedures and be performed by qualified personnel using approved equipment.
The manufacturing quality of a bimetallic PG clamp directly affects its suitability for electrical infrastructure projects.
Reacon pays attention to material selection, machining accuracy, component assembly, and product inspection throughout the manufacturing process.
Depending on the agreed technical requirements, product inspection may cover the following areas:
Material Verification
Check the specified aluminum and copper materials to ensure that the components correspond to the approved product configuration.
Dimensional Inspection
Verify the groove dimensions, overall structure, and fastening positions to ensure compatibility with the specified conductor arrangement.
Contact Surface Inspection
Examine the conductive surfaces for visible defects, machining irregularities, and surface condition issues.
Fastening Component Inspection
Check bolts, nuts, and related components for dimensional consistency and proper assembly.
Electrical and Mechanical Performance
Relevant electrical conductivity, contact resistance, and mechanical performance tests can be arranged according to the applicable product specifications and customer requirements.
Final Inspection and Packaging
Inspect the completed connector before shipment to ensure that the product configuration and packaging correspond to the purchase order.
Different power distribution projects may require different conductor combinations, connector dimensions, and installation arrangements.
Reacon supports product customization discussions based on customer drawings, technical specifications, and project requirements.
Customization requirements may include:
• CAPG-C and other specified PG clamp configurations.
• Aluminum and copper material combinations.
• Main conductor and branch conductor dimensions.
• Groove dimensions and connector structure.
• Bolt and fastening component specifications.
• Surface protection requirements.
• Product identification and customized packaging.
• OEM manufacturing according to approved drawings.
For bulk orders and engineering projects, customers can provide conductor specifications, technical drawings, or reference samples for evaluation before production.
Our team can review the connection requirements and provide corresponding product information and quotations.
Q1: What is the difference between a standard PG clamp and a bimetallic PG clamp?
A standard PG clamp is generally designed for connections involving compatible conductor materials, such as aluminum-to-aluminum or copper-to-copper. A bimetallic PG clamp is specifically configured for connections involving different metals, particularly aluminum and copper.
Q2: Why is a tinned copper insert used in an aluminum-copper PG clamp?
A tinned copper insert provides a suitable copper contact interface. The tin coating also helps protect the copper surface and contributes to the material transition design.
Q3: Can a bimetallic PG clamp be used in electrical substations?
Yes. Suitable configurations can be used for connections between aluminum conductors and copper equipment terminals in substations, provided that the product dimensions and electrical ratings meet the installation requirements.
Q4: Is the CAPG-C PG clamp suitable for coastal distribution networks?
It can be considered for coastal installations requiring aluminum-to-copper conductor connections. The required corrosion protection and material specifications should be evaluated according to the local environmental conditions.
Q5: Can PG clamps be used for grounding and lightning protection systems?
Certain PG clamp configurations are used in grounding and lightning protection installations. However, the CAPG-C bimetallic model should only be selected for such applications when its electrical and mechanical specifications are suitable for the intended grounding connection.
Q6: What information is required for customized PG clamp production?
Customers should provide the conductor material, conductor dimensions, connection arrangement, required quantity, and technical drawings if available. These details help determine the appropriate product configuration.
Q7: Does Reacon accept orders based on customer drawings?
Yes. Reacon can discuss customized manufacturing based on customer drawings, technical specifications, and project requirements. OEM production and customized packaging can also be discussed.