WELCOME TO REACON
Products
Home » Products

Hot Products

Inquiry

Product Center

  • 24kV Outdoor Expulsion Drop-out Type Fuse Cutout | High Voltage Distribution Line Protection Device
    Drop-out fuse is the most commonly used short-circuit protection switch for 10-38kV distribution line branch lines and distribution transformers. It has the characteristics of economy, easy operation, and strong adaptability to outdoor environments. It is widely used in 10-38kV distribution lines and power distribution. The primary side of the transformer is used for protection and equipment switching and switching operations.
  • 27kV Load Break Porcelain Fuse — Reliable High Voltage Protection for Overhead Distribution Systems
    Drop type fuse is the most commonly used short-circuit protection switch for 10kV distribution line branch lines and distribution transformers. It has the characteristics of economy, easy operation, and strong adaptability to outdoor environments.
  • 45kV Porcelain Load Break Fuse Cutout | High Voltage Fusibles with Load Break for Power Distribution
    Drop type fuse is the most commonly used short-circuit protection switch for 10kV distribution line branch lines and distribution transformers. It has the characteristics of economy, easy operation, and strong adaptability to outdoor environments.
  • 38kV Fusibles with Load Break – Porcelain Type | Reliable High Voltage Protection Device
    Drop type fuse is the most commonly used short-circuit protection switch for 10kV distribution line branch lines and distribution transformers. It has the characteristics of economy, easy operation, and strong adaptability to outdoor environments.
  • Reacon Porcelain Insulator for Overhead Distribution and Transmission Lines
    Porcelain insulators are insulators made of electrical ceramics as insulation components. Electrical ceramics are baked from quartz, feldspar, and clay as raw materials. The surface of porcelain insulators is usually covered with porcelain glaze to improve their mechanical strength, prevent water infiltration, and increase surface smoothness.
  • High-Performance 24kV 630A Outdoor AC Disconnect Switch | GWR-12/36 Weatherproof HV Isolator for Reliable Power Distribution
    An isolating switch (commonly referred to as a disconnector) is a specialized device in electrical engineering designed to safely separate circuits, creating a de-energized environment during equipment maintenance or system servicing. Its core function lies in providing a visible physical breakpoint to confirm circuit separation, ensuring personnel safety by eliminating residual current risks. Widely used in power transmission systems, industrial control terminals, and energy facilities, it is particularly critical for scenarios requiring power disconnection during mechanical adjustments or component replacements. Typical designs feature a rotary operating lever, insulation protection components, and visual open/close indicators, with advanced models incorporating grounding interlock functionality to enhance safety by connecting isolated sections to a grounding network. Notably, these devices lack arc suppression capabilities and must only operate after circuit breakers have de-energized the load, classifying them as passive safety components. Compliant with IEC, ANSI, and other international standards, they are essential for isolating high-voltage substation equipment (e.g., circuit breakers, transformers) during maintenance, serving as a foundational safeguard for secure power system operations.
  • 24kV 630A Outdoor High Voltage Isolator Switch | Durable Load Break & Safe Power Disconnection Solution
    An isolating switch (commonly referred to as a disconnector) is a specialized device in electrical engineering designed to safely separate circuits, creating a de-energized environment during equipment maintenance or system servicing. Its core function lies in providing a visible physical breakpoint to confirm circuit separation, ensuring personnel safety by eliminating residual current risks. Widely used in power transmission systems, industrial control terminals, and energy facilities, it is particularly critical for scenarios requiring power disconnection during mechanical adjustments or component replacements. Typical designs feature a rotary operating lever, insulation protection components, and visual open/close indicators, with advanced models incorporating grounding interlock functionality to enhance safety by connecting isolated sections to a grounding network. Notably, these devices lack arc suppression capabilities and must only operate after circuit breakers have de-energized the load, classifying them as passive safety components. Compliant with IEC, ANSI, and other international standards, they are essential for isolating high-voltage substation equipment (e.g., circuit breakers, transformers) during maintenance, serving as a foundational safeguard for secure power system operations.
You can provide us with the drawings, and we can customize the product for you. The delivery time depends on the product.

Quick Links

Product Category

Leave Us Your Info
Copyright © 2024 ZHEJIANG REACON ELECTRIC GROUP CO.,LTD. Sitemap.